Bellco Pachislo Instrukcja Naprawy Strona 5

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj
  • Strona
    / 12
  • Spis treści
  • BOOKMARKI
  • Oceniono. / 5. Na podstawie oceny klientów
Przeglądanie stron 4
Pachislo Slot Machine Operation Manual
5
are not spinning or there is not a bet or free play
on the machine. The inside reset key switch must
always be in the “OFF” position during game play.
MACHINE KEEPS PLAYING IN BONUS
GAME
This may be normal, keep playing until the bonus
game is complete. You may have to play as
many as 250 spins to complete the Bonus Game
(Big Chance Level).
COINS WILL NOT REGISTER, FALL
INTO COIN TRAY
Possible coin acceptor jam, check coin acceptor
and clear jam. Press reset button inside machine.
Machine only holds 50 credits at a time.
Additional coins inserted will fall into money tray.
Also, see above section titled “MACHINE DOES
NOT ACCEPT TOKENS.
HOPPER WILL NOT PAY OUT
Check payout hopper, make sure wire harness is
plugged in and secure. Check fuses.
TROUBLE CODES
Trouble Code Displayed on Front Door of
Machine:
HE - Hopper Empty - Not enough tokens for
payout. Add tokens to hopper.
HO - Hopper Out - Hopper is out of tokens. Add
tokens to hopper.
HJ - Hopper Jam - Remove coin hopper. Unplug
wiring harness and slide hopper out. Dump out
coins, some coins will remain in the lower hopper
area. To clear them, spin center of hopper until all
coins are free and hopper spins freely.
CE – Changer Error. Unplug and remove coin
acceptor. Look for oxidation on metallic portions
of coin path. If present remove with sandpaper or
emery cloth.
OLYMPIA/HEIWA MACHINES ONLY
E2 – Changer Error
E3 – Hopper Error
E4 – Hopper Error (normally caused when hopper
is jammed or unplugged.)
E5 – Hopper Error (normally jammed)
On the Olympia machines, if you get a hopper
error, try spraying the inside of the hopper with
WD-40 and spin the coin dispenser in the bottom
of the inside of the hopper (looks like a phone
dial). Wipe away excess WD-40 with a paper
towel. Refill coin hopper and test.
To clear error, reset machine by depressing
RESET switch either on power supply or on the
door.
Sometimes it is necessary to do a full reset. This
is done by following the odds reset procedure
listed above.
MACHINE VOLUME CONTROLS
Adjust volume control switch located on:
(1) Right side of speaker on inside of door near
coin tray.
(2) OR On inside of main door (as pictured
above).
Normally, speaker volume controls are three
position switches in the following locations:
OLYMPIA/HEIWA– Inside of door in the upper
part of door on right hand side (two three position
switches, both down for lowest setting)
ARUZE/ELECO/UNIVERSAL (3-reel) – On inside
of door under window for reels. All switches down
for lowest setting.
ARUZE/ELECO/UNIVERSAL (4 reel) – To left of
reels on the circuit board mounted on cabinet.
Two three position switches. Both in down
position for lowest setting
DAIDO – Two three position switches in the
center on the top of the inside of the door.
Przeglądanie stron 4
1 2 3 4 5 6 7 8 9 10 11 12

Komentarze do niniejszej Instrukcji

Brak uwag